{"id":6572,"date":"2022-09-22T15:03:38","date_gmt":"2022-09-22T13:03:38","guid":{"rendered":"https:\/\/www.novatest.it\/?post_type=civil-engineerings&#038;p=6572"},"modified":"2025-09-24T10:09:22","modified_gmt":"2025-09-24T08:09:22","slug":"nv-t24-det","status":"publish","type":"civil-engineerings","link":"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/","title":{"rendered":"NV-T24 DET"},"content":{"rendered":"\n<p>A single channel system for detensioning tests on reinforced concrete cables.<br>The system is available both in wired (via USB to PC) and wireless version, with receiver to PC or handheld system.<br>The system, in both versions, allows to measure the detensioning by means of a 120 or 350 Ohm linear strain gauge.<br>The strain gauge is connected via a metal bipolar connector, with a screw terminal block (other options are available on request).<br>The data are internally calibrated in microstrain in both systems, are then displayed in real time and saved in .csv format.<\/p>\n","protected":false},"featured_media":6566,"parent":0,"template":"","categories":[367,213],"tags":[],"civil_engineerings_cats":[200],"class_list":["post-6572","civil-engineerings","type-civil-engineerings","status-publish","has-post-thumbnail","hentry","category-prodotti-en","category-products","civil_engineerings_cats-concrete-investigation"],"acf":{"specifica_prodotto":"System for detensioning tests on steel and concrete structures","testo_breve_thumb_lista_prodotti":"System for detensioning tests on steel and concrete structures","contenuto_testuale_del_prodotto":"<p><strong>Measurement software<\/strong><\/p>\n<p>The software for the detensioning measurement allows the complete configuration of the system, both in wireless and cabalta versions, the real-time display of the data (both in graphical and numerical form) and their saving in .csv format on the PC (neither of the two systems has on-board memory).<br \/>\nVia software, calibrations are also available (with the possibility of linearization up to 9 points), zeroing, shunt (only for the wired version, for the wireless version an additional hardware component is available to be placed in parallel with the strain gauge itself).<\/p>\n","slider":[{"immagine":{"ID":6569,"id":6569,"title":"PhotoRoom_20220913_175619","filename":"PhotoRoom_20220913_175619.jpg","filesize":423694,"url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_175619.jpg","link":"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/photoroom_20220913_175619-2\/","alt":"","author":"4","description":"","caption":"","name":"photoroom_20220913_175619-2","status":"inherit","uploaded_to":6572,"date":"2022-09-22 12:44:28","modified":"2022-09-22 13:03:38","menu_order":0,"mime_type":"image\/jpeg","type":"image","subtype":"jpeg","icon":"https:\/\/www.novatest.it\/wp-includes\/images\/media\/default.png","width":1799,"height":2222,"sizes":{"thumbnail":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_175619-150x150.jpg","thumbnail-width":150,"thumbnail-height":150,"medium":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_175619-243x300.jpg","medium-width":243,"medium-height":300,"medium_large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_175619-768x949.jpg","medium_large-width":768,"medium_large-height":949,"large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_175619-829x1024.jpg","large-width":829,"large-height":1024,"1536x1536":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_175619-1244x1536.jpg","1536x1536-width":1244,"1536x1536-height":1536,"2048x2048":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_175619-1658x2048.jpg","2048x2048-width":1658,"2048x2048-height":2048,"medium-large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_175619.jpg","medium-large-width":520,"medium-large-height":642}}},{"immagine":{"ID":7197,"id":7197,"title":"estensimetro-01","filename":"estensimetro-01.jpeg","filesize":53031,"url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/estensimetro-01.jpeg","link":"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/estensimetro-01\/","alt":"","author":"4","description":"","caption":"","name":"estensimetro-01","status":"inherit","uploaded_to":6572,"date":"2023-04-21 14:33:44","modified":"2023-04-21 14:33:44","menu_order":0,"mime_type":"image\/jpeg","type":"image","subtype":"jpeg","icon":"https:\/\/www.novatest.it\/wp-includes\/images\/media\/default.png","width":477,"height":507,"sizes":{"thumbnail":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/estensimetro-01-150x150.jpeg","thumbnail-width":150,"thumbnail-height":150,"medium":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/estensimetro-01-282x300.jpeg","medium-width":282,"medium-height":300,"medium_large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/estensimetro-01.jpeg","medium_large-width":477,"medium_large-height":507,"large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/estensimetro-01.jpeg","large-width":477,"large-height":507,"1536x1536":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/estensimetro-01.jpeg","1536x1536-width":477,"1536x1536-height":507,"2048x2048":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/estensimetro-01.jpeg","2048x2048-width":477,"2048x2048-height":507,"medium-large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/estensimetro-01.jpeg","medium-large-width":477,"medium-large-height":507}}},{"immagine":{"ID":7199,"id":7199,"title":"estensimetro-02","filename":"estensimetro-02.png","filesize":266473,"url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/estensimetro-02.png","link":"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/estensimetro-02\/","alt":"","author":"4","description":"","caption":"","name":"estensimetro-02","status":"inherit","uploaded_to":6572,"date":"2023-04-21 14:33:45","modified":"2023-04-21 14:33:45","menu_order":0,"mime_type":"image\/png","type":"image","subtype":"png","icon":"https:\/\/www.novatest.it\/wp-includes\/images\/media\/default.png","width":1134,"height":954,"sizes":{"thumbnail":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/estensimetro-02-150x150.png","thumbnail-width":150,"thumbnail-height":150,"medium":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/estensimetro-02-300x252.png","medium-width":300,"medium-height":252,"medium_large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/estensimetro-02-768x646.png","medium_large-width":768,"medium_large-height":646,"large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/estensimetro-02-1024x861.png","large-width":1024,"large-height":861,"1536x1536":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/estensimetro-02.png","1536x1536-width":1134,"1536x1536-height":954,"2048x2048":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/estensimetro-02.png","2048x2048-width":1134,"2048x2048-height":954,"medium-large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/estensimetro-02.png","medium-large-width":520,"medium-large-height":437}}}],"caratteristiche_tecniche":"<p><strong>Strain gauges<\/strong><\/p>\n<p>The system is compatible with most strain gauges available on the market.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Electronics<\/strong><\/p>\n<p>The electronics, both in the wired and wireless version, have a 24-bit digitizer, stabilized 5V strain gauge power supply. The completion of the bridge is achieved through Vishay high stability and precision resistors. The wired system allows for shunt calibration through software command, while the wireless system requires an additional hardware module.<br \/>\nThe sampling rate can be adjusted by the user from 1 Hz up to 200 Hz (default 10 Hz).<br \/>\nThe zero is set through a specific software command managed by the user, both for the wireless and wired systems.<br \/>\nThe wireless system is powered by 2 AAA batteries, while the wired system is directly powered by USB.<\/p>\n","accessori":"","documento_allegato":[{"file":{"ID":10115,"id":10115,"title":"Novatest_ST_NV-T24 DET_EN","filename":"Novatest_ST_NV-T24-DET_EN.pdf","filesize":918397,"url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/Novatest_ST_NV-T24-DET_EN.pdf","link":"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/novatest_st_nv-t24-det_en\/","alt":"","author":"4","description":"","caption":"","name":"novatest_st_nv-t24-det_en","status":"inherit","uploaded_to":6572,"date":"2025-09-24 08:09:17","modified":"2025-09-24 08:09:17","menu_order":0,"mime_type":"application\/pdf","type":"application","subtype":"pdf","icon":"https:\/\/www.novatest.it\/wp-includes\/images\/media\/document.png"},"nome_file":"Technical sheet EN"}],"richiedi_noleggio":false,"sokkia":false,"prodotti_correlati":[{"ID":2701,"post_author":"4","post_date":"2020-08-07 16:18:49","post_date_gmt":"2020-08-07 14:18:49","post_content":"<!-- wp:paragraph -->\n<p><strong>Hydraulic system for extraction tests<\/strong> <strong>compliant with UNI EN12504: 3<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>The PULL-OUT STD KIT is a complete and reliable solution to perform incredibly reliable structural investigations.<br>The Pull-Out extraction test is classified among the semi-destructive investigation methods and consists in the measurement of the force necessary to extract a plug (pre-inserted or post-inserted) with controlled expansion in a special hole made specifically in the concrete as established by the reference standard (UNI EN12504: 3). In this way it is possible to make an estimate of the strength of the concrete directly on site and the evaluation of the mechanical characteristics of the material.<br>The system can be adapted for carrying out pull tests on threaded bars, anchors and anchors of various kinds.<\/p>\n<!-- \/wp:paragraph -->","post_title":"KIT PULL-OUT STD","post_excerpt":"","post_status":"publish","comment_status":"closed","ping_status":"closed","post_password":"","post_name":"kit-pull-out-std","to_ping":"","pinged":"","post_modified":"2025-03-28 10:14:35","post_modified_gmt":"2025-03-28 09:14:35","post_content_filtered":"","post_parent":0,"guid":"https:\/\/www.novatest.it\/?post_type=civil-engineerings&#038;p=2701","menu_order":64,"post_type":"civil-engineerings","post_mime_type":"","comment_count":"0","filter":"raw"},{"ID":2815,"post_author":"4","post_date":"2020-08-24 12:34:51","post_date_gmt":"2020-08-24 10:34:51","post_content":"<!-- wp:paragraph -->\n<p><strong>Multifunction rebar locator to ensure maximum precision in structural investigations<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p><strong>Novascan R630A <\/strong>is used to determine the localization and distribution of rebar, the measurement of the thickness of rebar cover and the diameter of bars.<\/p>\n<!-- \/wp:paragraph -->","post_title":"NOVASCAN R630A","post_excerpt":"","post_status":"publish","comment_status":"closed","ping_status":"closed","post_password":"","post_name":"novascan-r630a","to_ping":"","pinged":"","post_modified":"2025-03-28 10:19:56","post_modified_gmt":"2025-03-28 09:19:56","post_content_filtered":"","post_parent":0,"guid":"https:\/\/www.novatest.it\/?post_type=civil-engineerings&#038;p=2815","menu_order":49,"post_type":"civil-engineerings","post_mime_type":"","comment_count":"0","filter":"raw"},{"ID":6286,"post_author":"4","post_date":"2022-03-30 11:24:14","post_date_gmt":"2022-03-30 09:24:14","post_content":"<!-- wp:paragraph -->\n<p>The GPR SUBvysor 1500 is suitable for concrete structure inspection and searching of both metallic and dielectric objects (cracks, voids, rebars, etc.).<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>With GPR SUBvysor 1500, you can quickly detect position and depth of metallic and non-metallic objects:<br>\u2022 metal utilities, including pipes and cables;<br>\u2022 non-metallic pipes, including PVC and asbestos cement ones;<br>\u2022 positions of rebars;<br>\u2022 moisture zones;<br>\u2022 subsurface objects (voids, cracks, heterogeneous inclusions).<\/p>\n<!-- \/wp:paragraph -->","post_title":"GPR SUBvysor 1500","post_excerpt":"","post_status":"publish","comment_status":"closed","ping_status":"closed","post_password":"","post_name":"gpr-subvysor-1500","to_ping":"","pinged":"","post_modified":"2026-04-14 12:53:27","post_modified_gmt":"2026-04-14 10:53:27","post_content_filtered":"","post_parent":0,"guid":"https:\/\/www.novatest.it\/?post_type=civil-engineerings&#038;p=6286","menu_order":32,"post_type":"civil-engineerings","post_mime_type":"","comment_count":"0","filter":"raw"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>NV-T24 DET - Novatest Srl<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"NV-T24 DET - Novatest Srl\" \/>\n<meta property=\"og:description\" content=\"A single channel system for detensioning tests on reinforced concrete cables.The system is available both in wired (via USB to...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/\" \/>\n<meta property=\"og:site_name\" content=\"Novatest Srl\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-24T08:09:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_170343.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1800\" \/>\n\t<meta property=\"og:image:height\" content=\"2025\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/\",\"url\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/\",\"name\":\"NV-T24 DET - Novatest Srl\",\"isPartOf\":{\"@id\":\"https:\/\/www.novatest.it\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_170343.jpg\",\"datePublished\":\"2022-09-22T13:03:38+00:00\",\"dateModified\":\"2025-09-24T08:09:22+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/#primaryimage\",\"url\":\"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_170343.jpg\",\"contentUrl\":\"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_170343.jpg\",\"width\":1800,\"height\":2025},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.novatest.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Civil Engineering\",\"item\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"NV-T24 DET\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.novatest.it\/en\/#website\",\"url\":\"https:\/\/www.novatest.it\/en\/\",\"name\":\"Novatest Srl\",\"description\":\"Produciamo e commercializziamo strumenti tecnologici per la diagnostica non distruttiva.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.novatest.it\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"NV-T24 DET - Novatest Srl","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/","og_locale":"en_US","og_type":"article","og_title":"NV-T24 DET - Novatest Srl","og_description":"A single channel system for detensioning tests on reinforced concrete cables.The system is available both in wired (via USB to...","og_url":"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/","og_site_name":"Novatest Srl","article_modified_time":"2025-09-24T08:09:22+00:00","og_image":[{"width":1800,"height":2025,"url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_170343.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/","url":"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/","name":"NV-T24 DET - Novatest Srl","isPartOf":{"@id":"https:\/\/www.novatest.it\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/#primaryimage"},"image":{"@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/#primaryimage"},"thumbnailUrl":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_170343.jpg","datePublished":"2022-09-22T13:03:38+00:00","dateModified":"2025-09-24T08:09:22+00:00","breadcrumb":{"@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/#primaryimage","url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_170343.jpg","contentUrl":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_170343.jpg","width":1800,"height":2025},{"@type":"BreadcrumbList","@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/nv-t24-det\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.novatest.it\/en\/"},{"@type":"ListItem","position":2,"name":"Civil Engineering","item":"https:\/\/www.novatest.it\/en\/civil-engineerings\/"},{"@type":"ListItem","position":3,"name":"NV-T24 DET"}]},{"@type":"WebSite","@id":"https:\/\/www.novatest.it\/en\/#website","url":"https:\/\/www.novatest.it\/en\/","name":"Novatest Srl","description":"Produciamo e commercializziamo strumenti tecnologici per la diagnostica non distruttiva.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.novatest.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"uagb_featured_image_src":{"full":["https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_170343.jpg",1800,2025,false],"thumbnail":["https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_170343-150x150.jpg",150,150,true],"medium":["https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_170343-267x300.jpg",267,300,true],"medium_large":["https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_170343-768x864.jpg",768,864,true],"large":["https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_170343-910x1024.jpg",910,1024,true],"1536x1536":["https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_170343-1365x1536.jpg",1365,1536,true],"2048x2048":["https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_170343.jpg",1800,2025,false],"medium-large":["https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_170343.jpg",520,585,false]},"uagb_author_info":{"display_name":"Uaoh","author_link":"https:\/\/www.novatest.it\/en\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"A single channel system for detensioning tests on reinforced concrete cables.The system is available both in wired (via USB to...","img_url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2022\/09\/PhotoRoom_20220913_170343.jpg","_links":{"self":[{"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/civil-engineerings\/6572","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/civil-engineerings"}],"about":[{"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/types\/civil-engineerings"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/media\/6566"}],"wp:attachment":[{"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/media?parent=6572"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/categories?post=6572"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/tags?post=6572"},{"taxonomy":"civil_engineerings_cats","embeddable":true,"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/civil_engineerings_cats?post=6572"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}