{"id":4123,"date":"2020-12-04T12:34:43","date_gmt":"2020-12-04T11:34:43","guid":{"rendered":"https:\/\/www.novatest.it\/?post_type=civil-engineerings&#038;p=4123"},"modified":"2026-07-02T09:52:16","modified_gmt":"2026-07-02T07:52:16","slug":"a1040-mira-3d","status":"publish","type":"civil-engineerings","link":"https:\/\/www.novatest.it\/en\/civil-engineerings\/a1040-mira-3d\/","title":{"rendered":"A1040 MIRA 3D"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>Ultimate ultrasonic tomography for quality assessment of concrete structures<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A1040 MIRA 3D is a low frequency ultrasonic tomography system suitable for manual and automated assessment concrete structures. Due to its novel A-DPC\u00ae sensor technology, it provides unbeatable penetration depth, inspection sensitivity and imaging resolution by implementing three-dimensional FMC \/ TFM in each instrument position.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The instrument consists of lightweight body with 4 x 8 Active Dry-Point-Contact transducers with integrated pulser-received circuits and parallel DAQ electronics wirelessly connected to the powerful smartphone that implements image reconstruction and visualization algorithms by means of parallel graphic processor units on-board. This hardware solution allows achieving highest performance for real-time 3D-TFM imaging.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">By using special transmitting techniques such as enhanced burst energy an outstanding penetration depth has been achieved even by using relatively small active aperture of the instrument. Although, for additional extending the inspection range arbitrary aperture extension can be utilized by two and more array units in one configuration.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">INTROVIEW\u00ae Pro \u2013 Desktop or Laptop software for remote unit control and 3D visualization &amp; analysis of Big Data is an essential part of the instrument delivered in the standard delivery set. The open data format for customized developments by user \u2013 for offline as well as online applications \u2013 complete the functional package of this extraordinary instrument.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"A1040 MIRA 3D - Ultrasonic Tomograph for Nondestructive Concrete Testing\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/T1_bpJJ-6Zc?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n","protected":false},"featured_media":5387,"parent":0,"template":"","categories":[],"tags":[],"civil_engineerings_cats":[275,200,202,203],"class_list":["post-4123","civil-engineerings","type-civil-engineerings","status-publish","has-post-thumbnail","hentry","civil_engineerings_cats-in-evidenza-en-2","civil_engineerings_cats-concrete-investigation","civil_engineerings_cats-wood-investigation","civil_engineerings_cats-rock-testing"],"acf":{"specifica_prodotto":"A1040 MIRA 3D","testo_breve_thumb_lista_prodotti":"Ultimate ultrasonic tomograph for quality assessment of concrete structures ","contenuto_testuale_del_prodotto":"<p>The ultrasonic tomograph A1040 MIRA 3D is the best solution for ultrasonic testing of highly scattering materials, such us concrete and reinforced concrete, stones, rock, composites, ceramics, wood, epoxy, refractory materials. Among others, following main applications can be mentioned as application fields of the instrument:<\/p>\n<ul>\n<li>Localization of reinforcement rebars and other elements (tendon ducts, anchors, hollow pipes, cables, hollow pipes), also beyond of rebar layers<\/li>\n<li>Detection of material voids, estimation of their position and size in 3D: cavities, inclusions, honeycombs, cracks<\/li>\n<li>Thickness measurement by one-side access<\/li>\n<li>Detection of grouting defects in tendon ducts and grouting couplers<\/li>\n<li>Assessment of fireproof stones<\/li>\n<\/ul>\n","slider":[{"immagine":{"ID":4135,"id":4135,"title":"Cattura 2","filename":"Cattura-2-1.jpg","filesize":37480,"url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/Cattura-2-1.jpg","link":"https:\/\/www.novatest.it\/en\/civil-engineerings\/a1040-mira-3d\/cattura-2-2-2\/","alt":"","author":"4","description":"","caption":"","name":"cattura-2-2-2","status":"inherit","uploaded_to":4123,"date":"2020-12-04 11:32:47","modified":"2020-12-04 11:32:47","menu_order":0,"mime_type":"image\/jpeg","type":"image","subtype":"jpeg","icon":"https:\/\/www.novatest.it\/wp-includes\/images\/media\/default.png","width":523,"height":430,"sizes":{"thumbnail":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/Cattura-2-1-150x150.jpg","thumbnail-width":150,"thumbnail-height":150,"medium":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/Cattura-2-1-300x247.jpg","medium-width":300,"medium-height":247,"medium_large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/Cattura-2-1.jpg","medium_large-width":523,"medium_large-height":430,"large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/Cattura-2-1.jpg","large-width":523,"large-height":430,"1536x1536":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/Cattura-2-1.jpg","1536x1536-width":523,"1536x1536-height":430,"2048x2048":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/Cattura-2-1.jpg","2048x2048-width":523,"2048x2048-height":430,"medium-large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/Cattura-2-1.jpg","medium-large-width":520,"medium-large-height":428}}},{"immagine":{"ID":5373,"id":5373,"title":"A1040MIRA_PRO_01","filename":"A1040MIRA_PRO_01.jpg","filesize":61057,"url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/A1040MIRA_PRO_01.jpg","link":"https:\/\/www.novatest.it\/en\/civil-engineerings\/a1040-mira-3d\/a1040mira_pro_01-2\/","alt":"","author":"4","description":"","caption":"","name":"a1040mira_pro_01-2","status":"inherit","uploaded_to":4123,"date":"2021-09-16 12:57:55","modified":"2021-09-16 12:57:55","menu_order":0,"mime_type":"image\/jpeg","type":"image","subtype":"jpeg","icon":"https:\/\/www.novatest.it\/wp-includes\/images\/media\/default.png","width":1080,"height":1080,"sizes":{"thumbnail":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/A1040MIRA_PRO_01-150x150.jpg","thumbnail-width":150,"thumbnail-height":150,"medium":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/A1040MIRA_PRO_01-300x300.jpg","medium-width":300,"medium-height":300,"medium_large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/A1040MIRA_PRO_01-768x768.jpg","medium_large-width":768,"medium_large-height":768,"large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/A1040MIRA_PRO_01-1024x1024.jpg","large-width":1024,"large-height":1024,"1536x1536":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/A1040MIRA_PRO_01.jpg","1536x1536-width":1080,"1536x1536-height":1080,"2048x2048":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/A1040MIRA_PRO_01.jpg","2048x2048-width":1080,"2048x2048-height":1080,"medium-large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/A1040MIRA_PRO_01.jpg","medium-large-width":520,"medium-large-height":520}}},{"immagine":{"ID":5375,"id":5375,"title":"A1040MIRA_PRO_02","filename":"A1040MIRA_PRO_02.jpg","filesize":89222,"url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/A1040MIRA_PRO_02.jpg","link":"https:\/\/www.novatest.it\/en\/civil-engineerings\/a1040-mira-3d\/a1040mira_pro_02-2\/","alt":"","author":"4","description":"","caption":"","name":"a1040mira_pro_02-2","status":"inherit","uploaded_to":4123,"date":"2021-09-16 12:58:04","modified":"2021-09-16 12:58:04","menu_order":0,"mime_type":"image\/jpeg","type":"image","subtype":"jpeg","icon":"https:\/\/www.novatest.it\/wp-includes\/images\/media\/default.png","width":1080,"height":1080,"sizes":{"thumbnail":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/A1040MIRA_PRO_02-150x150.jpg","thumbnail-width":150,"thumbnail-height":150,"medium":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/A1040MIRA_PRO_02-300x300.jpg","medium-width":300,"medium-height":300,"medium_large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/A1040MIRA_PRO_02-768x768.jpg","medium_large-width":768,"medium_large-height":768,"large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/A1040MIRA_PRO_02-1024x1024.jpg","large-width":1024,"large-height":1024,"1536x1536":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/A1040MIRA_PRO_02.jpg","1536x1536-width":1080,"1536x1536-height":1080,"2048x2048":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/A1040MIRA_PRO_02.jpg","2048x2048-width":1080,"2048x2048-height":1080,"medium-large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/A1040MIRA_PRO_02.jpg","medium-large-width":520,"medium-large-height":520}}}],"caratteristiche_tecniche":"<ul>\n<li>Instrument type Multi-channel ultrasonic pulse echo tomograph with built-in matrix transducer array<\/li>\n<li>Number of channels: 32 (extendable to 64, 96 etc.)<\/li>\n<li>Number of independent elements in the matrix transducer aperture: 32 (extendable to 64, 96 etc.)<\/li>\n<li>Type of the ultrasonic transducers: Active dry point contact (A-DPC) transducers with ceramic wear proof tips and integrated pulser-receiver electronics<\/li>\n<li>Bandwidth: from 10 to 90 kHz<\/li>\n<li>Material sound velocity range: from 1.000 to 4.000 m\/s (from 40 to 157 inches\/s)<\/li>\n<li>Maximum penetration depth in concrete: up to 3.000 mm (118 inch)<\/li>\n<li>Maximum penetration depth in reinforced concrete: up to 1.000 mm (400 inch)<\/li>\n<li>Power supply: Exchangeable Li-Ion battery 18650<\/li>\n<li>Battery operation time: up to 10 hours<\/li>\n<li>Maximum dimensions of one unit without handles: 200x125x100 mm (7,9 x 4,9 x 3,9 inch)<\/li>\n<li>Maximum weight of the electronic unit with the batteries, handles and tablet PC mounted: 3.5 kg<\/li>\n<li>Air temperature range: from -10 to + 50 \u00b0\u0421 (from 14 to 122\u00b0F)<\/li>\n<li>Relative air humidity at +35\u00b0\u0421 \/ 95\u00b0F, max. 95 %<br \/>\nAverage service life, min. 5 years<\/li>\n<\/ul>\n","accessori":"<ul>\n<li>N.\u00b0 1 Electronic unit A1040 MIRA 3D with 32 x A-DPC\u00ae transducers<\/li>\n<li>N.\u00b0 1 Tablet-PC with protective case<\/li>\n<li>N.\u00b0 1 Reference block for regular functional tests<\/li>\n<li>N.\u00b0 6 Exchangeable Li-Ion battery 18650<\/li>\n<li>N.\u00b0 2 Type C power supply<\/li>\n<li>N.\u00b0 2 Data cable USB Type C<\/li>\n<li>N.\u00b0 1 INTROVIEW\u00ae Pro Software with 12 Months Update &amp; Support service<\/li>\n<li>N.\u00b0 1Hard case<\/li>\n<li>Warranty certificate<\/li>\n<li>Operating Manual<\/li>\n<li>N.\u00b0 2 for battery exchange<\/li>\n<\/ul>\n","documento_allegato":[{"file":{"ID":10693,"id":10693,"title":"A1040_MIRA_3D_Advertising_Booklet","filename":"A1040_MIRA_3D_Advertising_Booklet.pdf","filesize":1058819,"url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/A1040_MIRA_3D_Advertising_Booklet.pdf","link":"https:\/\/www.novatest.it\/en\/civil-engineerings\/a1040-mira-3d\/a1040_mira_3d_advertising_booklet\/","alt":"","author":"4","description":"","caption":"","name":"a1040_mira_3d_advertising_booklet","status":"inherit","uploaded_to":4123,"date":"2026-04-15 08:19:05","modified":"2026-04-15 08:19:05","menu_order":0,"mime_type":"application\/pdf","type":"application","subtype":"pdf","icon":"https:\/\/www.novatest.it\/wp-includes\/images\/media\/document.png"},"nome_file":"Technical Sheet"}],"richiedi_noleggio":true,"prodotti_correlati":[{"ID":6286,"post_author":"4","post_date":"2022-03-30 11:24:14","post_date_gmt":"2022-03-30 09:24:14","post_content":"<!-- wp:paragraph -->\n<p>The GPR SUBvysor 1500 is suitable for concrete structure inspection and searching of both metallic and dielectric objects (cracks, voids, rebars, etc.).<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>With GPR SUBvysor 1500, you can quickly detect position and depth of metallic and non-metallic objects:<br>\u2022 metal utilities, including pipes and cables;<br>\u2022 non-metallic pipes, including PVC and asbestos cement ones;<br>\u2022 positions of rebars;<br>\u2022 moisture zones;<br>\u2022 subsurface objects (voids, cracks, heterogeneous inclusions).<\/p>\n<!-- \/wp:paragraph -->","post_title":"GPR SUBvysor 1500","post_excerpt":"","post_status":"publish","comment_status":"closed","ping_status":"closed","post_password":"","post_name":"gpr-subvysor-1500","to_ping":"","pinged":"","post_modified":"2026-04-14 12:53:27","post_modified_gmt":"2026-04-14 10:53:27","post_content_filtered":"","post_parent":0,"guid":"https:\/\/www.novatest.it\/?post_type=civil-engineerings&#038;p=6286","menu_order":20,"post_type":"civil-engineerings","post_mime_type":"","comment_count":"0","filter":"raw"},{"ID":11077,"post_author":"4","post_date":"2026-07-01 15:05:37","post_date_gmt":"2026-07-01 13:05:37","post_content":"<!-- wp:paragraph -->\n<p><strong>HIKMICRO SP Series \u2014 Professional Handheld Thermal Camera<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>The\u00a0<strong>HIKMICRO SP Series<\/strong>\u00a0is the professional handheld thermal camera line designed for technicians, inspectors, and maintenance engineers working in industrial, energy, and construction environments. Four models across two resolution tiers:\u00a0<strong>SP40<\/strong>\u00a0and\u00a0<strong>SP40H<\/strong>\u00a0with a\u00a0<strong>480 \u00d7 360 pixel<\/strong>\u00a0detector,\u00a0<strong>SP60<\/strong>\u00a0and\u00a0<strong>SP60H<\/strong>\u00a0with a\u00a0<strong>640 \u00d7 480 pixel<\/strong>\u00a0detector \u2014 all equipped with\u00a0<strong>SuperIR<\/strong>\u00a0technology that quadruples image resolution on capture, delivering 960 \u00d7 720 and 1,280 \u00d7 960 pixel radiometric images respectively for superior diagnostic report quality.<\/p>\n<!-- \/wp:paragraph -->","post_title":"HIKMICRO SP40\/SP60 Thermal Camera","post_excerpt":"","post_status":"publish","comment_status":"closed","ping_status":"closed","post_password":"","post_name":"hikmicro-sp40-sp60-thermal-camera","to_ping":"","pinged":"","post_modified":"2026-07-02 10:10:41","post_modified_gmt":"2026-07-02 08:10:41","post_content_filtered":"","post_parent":0,"guid":"https:\/\/www.novatest.it\/?post_type=civil-engineerings&#038;p=11077","menu_order":23,"post_type":"civil-engineerings","post_mime_type":"","comment_count":"0","filter":"raw"},{"ID":11088,"post_author":"4","post_date":"2026-07-01 15:34:13","post_date_gmt":"2026-07-01 13:34:13","post_content":"<!-- wp:paragraph -->\n<p>The U-4620 is the world's first truly cable-free ultrasonic pulse velocity (UPV) tester, developed for non-destructive testing of concrete. Its wireless RF synchronisation technology removes every cable between transmitter and receiver \u2014 say goodbye to the cumbersome, failure-prone connections of traditional UPV systems.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>The compact, lightweight design enables true single-operator use, cutting setup time and boosting on-site productivity. The instrument measures pulse velocity to assess concrete strength, homogeneity, cracks, voids and elastic properties without damaging the structure.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>Three operating modes (time\/velocity, crack depth and parameter), a high-resolution display integrated in the receiver, internal memory, Bluetooth and PC connectivity via USB-C, and PDF\/Excel report generation through dedicated App and software. Accuracy \u00b10.1%, range up to 10 m, battery life up to 8 hours. Compliant with IS, BS-4408, BS-1881 and ASTM C-597 standards.<\/p>\n<!-- \/wp:paragraph -->","post_title":"U-4620","post_excerpt":"","post_status":"publish","comment_status":"closed","ping_status":"closed","post_password":"","post_name":"u-4620","to_ping":"","pinged":"","post_modified":"2026-07-02 10:13:40","post_modified_gmt":"2026-07-02 08:13:40","post_content_filtered":"","post_parent":0,"guid":"https:\/\/www.novatest.it\/?post_type=civil-engineerings&#038;p=11088","menu_order":64,"post_type":"civil-engineerings","post_mime_type":"","comment_count":"0","filter":"raw"}],"sokkia":false},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>A1040 MIRA 3D - Novatest Srl<\/title>\n<meta name=\"description\" content=\"Ultimate ultrasonic tomograph for quality assessment of concrete structures.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.novatest.it\/en\/civil-engineerings\/a1040-mira-3d\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"A1040 MIRA 3D - Novatest Srl\" \/>\n<meta property=\"og:description\" content=\"Ultimate ultrasonic tomograph for quality assessment of concrete structures.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.novatest.it\/en\/civil-engineerings\/a1040-mira-3d\/\" \/>\n<meta property=\"og:site_name\" content=\"Novatest Srl\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-02T07:52:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/a1040-mira-3d.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.novatest.it\\\/en\\\/civil-engineerings\\\/a1040-mira-3d\\\/\",\"url\":\"https:\\\/\\\/www.novatest.it\\\/en\\\/civil-engineerings\\\/a1040-mira-3d\\\/\",\"name\":\"A1040 MIRA 3D - Novatest Srl\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.novatest.it\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.novatest.it\\\/en\\\/civil-engineerings\\\/a1040-mira-3d\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.novatest.it\\\/en\\\/civil-engineerings\\\/a1040-mira-3d\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.novatest.it\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/a1040-mira-3d.jpg\",\"datePublished\":\"2020-12-04T11:34:43+00:00\",\"dateModified\":\"2026-07-02T07:52:16+00:00\",\"description\":\"Ultimate ultrasonic tomograph for quality assessment of concrete structures.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.novatest.it\\\/en\\\/civil-engineerings\\\/a1040-mira-3d\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.novatest.it\\\/en\\\/civil-engineerings\\\/a1040-mira-3d\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.novatest.it\\\/en\\\/civil-engineerings\\\/a1040-mira-3d\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.novatest.it\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/a1040-mira-3d.jpg\",\"contentUrl\":\"https:\\\/\\\/www.novatest.it\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/a1040-mira-3d.jpg\",\"width\":600,\"height\":600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.novatest.it\\\/en\\\/civil-engineerings\\\/a1040-mira-3d\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.novatest.it\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Civil Engineering\",\"item\":\"https:\\\/\\\/www.novatest.it\\\/en\\\/civil-engineerings\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"A1040 MIRA 3D\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.novatest.it\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.novatest.it\\\/en\\\/\",\"name\":\"Novatest Srl\",\"description\":\"Produciamo e commercializziamo strumenti tecnologici per la diagnostica non distruttiva.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.novatest.it\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"A1040 MIRA 3D - Novatest Srl","description":"Ultimate ultrasonic tomograph for quality assessment of concrete structures.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.novatest.it\/en\/civil-engineerings\/a1040-mira-3d\/","og_locale":"en_US","og_type":"article","og_title":"A1040 MIRA 3D - Novatest Srl","og_description":"Ultimate ultrasonic tomograph for quality assessment of concrete structures.","og_url":"https:\/\/www.novatest.it\/en\/civil-engineerings\/a1040-mira-3d\/","og_site_name":"Novatest Srl","article_modified_time":"2026-07-02T07:52:16+00:00","og_image":[{"width":600,"height":600,"url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/a1040-mira-3d.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/a1040-mira-3d\/","url":"https:\/\/www.novatest.it\/en\/civil-engineerings\/a1040-mira-3d\/","name":"A1040 MIRA 3D - Novatest Srl","isPartOf":{"@id":"https:\/\/www.novatest.it\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/a1040-mira-3d\/#primaryimage"},"image":{"@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/a1040-mira-3d\/#primaryimage"},"thumbnailUrl":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/a1040-mira-3d.jpg","datePublished":"2020-12-04T11:34:43+00:00","dateModified":"2026-07-02T07:52:16+00:00","description":"Ultimate ultrasonic tomograph for quality assessment of concrete structures.","breadcrumb":{"@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/a1040-mira-3d\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.novatest.it\/en\/civil-engineerings\/a1040-mira-3d\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/a1040-mira-3d\/#primaryimage","url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/a1040-mira-3d.jpg","contentUrl":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/a1040-mira-3d.jpg","width":600,"height":600},{"@type":"BreadcrumbList","@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/a1040-mira-3d\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.novatest.it\/en\/"},{"@type":"ListItem","position":2,"name":"Civil Engineering","item":"https:\/\/www.novatest.it\/en\/civil-engineerings\/"},{"@type":"ListItem","position":3,"name":"A1040 MIRA 3D"}]},{"@type":"WebSite","@id":"https:\/\/www.novatest.it\/en\/#website","url":"https:\/\/www.novatest.it\/en\/","name":"Novatest Srl","description":"Produciamo e commercializziamo strumenti tecnologici per la diagnostica non distruttiva.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.novatest.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"uagb_featured_image_src":{"full":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/a1040-mira-3d.jpg",600,600,false],"thumbnail":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/a1040-mira-3d-150x150.jpg",150,150,true],"medium":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/a1040-mira-3d-300x300.jpg",300,300,true],"medium_large":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/a1040-mira-3d.jpg",600,600,false],"large":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/a1040-mira-3d.jpg",600,600,false],"1536x1536":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/a1040-mira-3d.jpg",600,600,false],"2048x2048":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/a1040-mira-3d.jpg",600,600,false],"medium-large":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/a1040-mira-3d.jpg",520,520,false]},"uagb_author_info":{"display_name":"Uaoh","author_link":"https:\/\/www.novatest.it\/en\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"Ultimate ultrasonic tomography for quality assessment of concrete structures A1040 MIRA 3D is a low frequency ultrasonic tomography system suitable...","img_url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/12\/a1040-mira-3d.jpg","_links":{"self":[{"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/civil-engineerings\/4123","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/civil-engineerings"}],"about":[{"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/types\/civil-engineerings"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/media\/5387"}],"wp:attachment":[{"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/media?parent=4123"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/categories?post=4123"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/tags?post=4123"},{"taxonomy":"civil_engineerings_cats","embeddable":true,"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/civil_engineerings_cats?post=4123"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}