{"id":2698,"date":"2020-08-07T15:40:58","date_gmt":"2020-08-07T13:40:58","guid":{"rendered":"https:\/\/www.novatest.it\/?post_type=civil-engineerings&#038;p=2698"},"modified":"2025-03-28T10:12:36","modified_gmt":"2025-03-28T09:12:36","slug":"kit-pull-off-500","status":"publish","type":"civil-engineerings","link":"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/","title":{"rendered":"KIT PULL-OFF 500"},"content":{"rendered":"\n<p><strong>Hydraulic system for tear adherence tests on high resistance coating materials<\/strong><\/p>\n\n\n\n<p>The Pull-Off is a direct method of proof consists of a semi-destructive extraction, used to estimate the tensile strength of materials. Recovery linked to the substrate, such as wall cladding (plaster or other).<\/p>\n","protected":false},"featured_media":3447,"parent":0,"template":"","categories":[],"tags":[],"civil_engineerings_cats":[204],"class_list":["post-2698","civil-engineerings","type-civil-engineerings","status-publish","has-post-thumbnail","hentry","civil_engineerings_cats-extraction-testing"],"acf":{"specifica_prodotto":"KIT PULL-OFF 500","testo_breve_thumb_lista_prodotti":"Hydraulic system for tear adherence tests on high resistance coating materials","contenuto_testuale_del_prodotto":"<p>The test is prepared by pasting directly on the surface of the material to investigate, in an area specially designed with appropriate resins, a circular metal plate \u00d8 50 mm.<\/p>\n<p>Before the test is performed along the cutting edge of metal plate in order to release the evidence from the surrounding area.<br \/>\nThe cut should have a depth at least equal to the thickness of the coating. Maturation occurred at the resin by the application to the hard pressure of posting in the direction normal to the wall jack should be fitted with calibrated pressure gauge, which exercises opposing force on a support structure.<\/p>\n","slider":[{"immagine":{"ID":1224,"id":1224,"title":"Kit-Pull-Off_1-1","filename":"Kit-Pull-Off_1-1.png","filesize":350431,"url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit-Pull-Off_1-1.png","link":"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/kit-pull-off_1-1-2\/","alt":"","author":"2","description":"","caption":"","name":"kit-pull-off_1-1-2","status":"inherit","uploaded_to":2698,"date":"2020-06-30 09:08:30","modified":"2020-08-07 13:36:48","menu_order":0,"mime_type":"image\/png","type":"image","subtype":"png","icon":"https:\/\/www.novatest.it\/wp-includes\/images\/media\/default.png","width":581,"height":485,"sizes":{"thumbnail":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit-Pull-Off_1-1-150x150.png","thumbnail-width":150,"thumbnail-height":150,"medium":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit-Pull-Off_1-1-300x250.png","medium-width":300,"medium-height":250,"medium_large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit-Pull-Off_1-1.png","medium_large-width":581,"medium_large-height":485,"large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit-Pull-Off_1-1.png","large-width":581,"large-height":485,"1536x1536":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit-Pull-Off_1-1.png","1536x1536-width":581,"1536x1536-height":485,"2048x2048":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit-Pull-Off_1-1.png","2048x2048-width":581,"2048x2048-height":485,"medium-large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit-Pull-Off_1-1.png","medium-large-width":520,"medium-large-height":434}}}],"caratteristiche_tecniche":"<ul>\n<li>Single-stage lever pump, max working pressure 700 bar, 1.4 cc per stroke, useful reservoir capacity 0.5 liters (*)<\/li>\n<li>High-precision digital manometer NVT02B, 0-700 bar, with min\/max peak indication, selectable units of measurement (psi, MPa, kPa, bar, mbar), accuracy 0.20% F.S. (*)<\/li>\n<li>Gauge holder with 1\/2\u201d G fitting (*)<\/li>\n<li>Hollow cylinder with single-acting spring return, 10-ton capacity, 50 mm stroke (**)<\/li>\n<li>Measurement range: 0-70 MPa<\/li>\n<li>Tripod reaction spacer with adjustable feet<\/li>\n<li>Pull rod for M10 anchors with M18 external thread<\/li>\n<li>Self-leveling head and lock nut (***)<\/li>\n<li>Plates \u00d8 50 mm (M10)<\/li>\n<li>High-strength flexible hose L=2 m with 3\/8\u201d NPT quick-connect screw couplings and protective caps (**)<\/li>\n<\/ul>\n<p>(*) Compatible with Pull-Out STD Kit, Flat Jack Kit, Plate Load Test Kit, and Tensile Load Test Kit<br \/>\n(**) Compatible with Pull-Out STD Kit and Plate Load Test Kit<br \/>\n(***) Compatible with Pull-Out STD Kit<\/p>\n","accessori":"<ul>\n<li>N.1 Single-stage lever pump 0-700 bar, low flow rate, 0.5 L (*)<\/li>\n<li>N.1 High-precision digital manometer 0-700 bar with min\/max peak indication, complete with calibration report (Accredia reference) (*)<\/li>\n<li>N.1 Gauge holder fitting (*)<\/li>\n<li>N.1 Hollow cylinder with single-acting spring return, 10-ton, 50 mm stroke (**)<\/li>\n<li>N.1 Tripod reaction spacer with adjustable feet<\/li>\n<li>N.1 Pull rod with self-leveling head and lock nut<\/li>\n<li>N.6 Plates \u00d8 50 mm<\/li>\n<li>Carrying case with trolley (*)<\/li>\n<li>Flexible hose with quick-connect screw couplings and protective caps (**)<\/li>\n<\/ul>\n<p>(*) Compatible with Pull-Out STD Kit, Flat Jack Kit, Plate Load Test Kit, and Tensile Load Test Kit<br \/>\n(**) Compatible with Pull-Out STD Kit and Plate Load Test Kit<br \/>\n(***) Compatible with Pull-Out STD Kit<\/p>\n","documento_allegato":[{"file":{"ID":9489,"id":9489,"title":"Novatest_ST_Kit_PullOff_500_ENG","filename":"Novatest_ST_Kit_PullOff_500_ENG.pdf","filesize":285375,"url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2025\/03\/Novatest_ST_Kit_PullOff_500_ENG.pdf","link":"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/novatest_st_kit_pulloff_500_eng-2\/","alt":"","author":"4","description":"","caption":"","name":"novatest_st_kit_pulloff_500_eng-2","status":"inherit","uploaded_to":2698,"date":"2025-03-28 09:12:05","modified":"2025-03-28 09:12:37","menu_order":0,"mime_type":"application\/pdf","type":"application","subtype":"pdf","icon":"https:\/\/www.novatest.it\/wp-includes\/images\/media\/document.png"},"nome_file":"Technical sheet"}],"richiedi_noleggio":true,"prodotti_correlati":[{"ID":2883,"post_author":"4","post_date":"2020-08-25 11:14:21","post_date_gmt":"2020-08-25 09:14:21","post_content":"<!-- wp:paragraph -->\n<p><strong>Hydraulic system for tear adherence tests on all coating materials<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>Measures adhesion of coatings to metal, wood, concrete and other rigid substrates Revolutionary self-alignment feature and pull rate indicator. Conforms to national and international standards including ASTM D4541\/D7234, ISO 4624\/16276-1, AS\/NZS 1580.408.5 and others.<\/p>\n<!-- \/wp:paragraph -->","post_title":"KIT PULL-OFF POSITEST","post_excerpt":"","post_status":"publish","comment_status":"closed","ping_status":"closed","post_password":"","post_name":"pull-off-positest","to_ping":"","pinged":"","post_modified":"2024-03-05 09:27:13","post_modified_gmt":"2024-03-05 08:27:13","post_content_filtered":"","post_parent":0,"guid":"https:\/\/www.novatest.it\/?post_type=civil-engineerings&#038;p=2883","menu_order":101,"post_type":"civil-engineerings","post_mime_type":"","comment_count":"0","filter":"raw"},{"ID":2698,"post_author":"4","post_date":"2020-08-07 15:40:58","post_date_gmt":"2020-08-07 13:40:58","post_content":"<!-- wp:paragraph -->\n<p><strong>Hydraulic system for tear adherence tests on high resistance coating materials<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>The Pull-Off is a direct method of proof consists of a semi-destructive extraction, used to estimate the tensile strength of materials. Recovery linked to the substrate, such as wall cladding (plaster or other).<\/p>\n<!-- \/wp:paragraph -->","post_title":"KIT PULL-OFF 500","post_excerpt":"","post_status":"publish","comment_status":"closed","ping_status":"closed","post_password":"","post_name":"kit-pull-off-500","to_ping":"","pinged":"","post_modified":"2025-03-28 10:12:36","post_modified_gmt":"2025-03-28 09:12:36","post_content_filtered":"","post_parent":0,"guid":"https:\/\/www.novatest.it\/?post_type=civil-engineerings&#038;p=2698","menu_order":98,"post_type":"civil-engineerings","post_mime_type":"","comment_count":"0","filter":"raw"}],"sokkia":false},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>KIT PULL-OFF 500 - Novatest Srl<\/title>\n<meta name=\"description\" content=\"Hydraulic system for tear adherence tests on high resistance coating materials.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"KIT PULL-OFF 500 - Novatest Srl\" \/>\n<meta property=\"og:description\" content=\"Hydraulic system for tear adherence tests on high resistance coating materials.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/\" \/>\n<meta property=\"og:site_name\" content=\"Novatest Srl\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-28T09:12:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit_Pull_Off-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/\",\"url\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/\",\"name\":\"KIT PULL-OFF 500 - Novatest Srl\",\"isPartOf\":{\"@id\":\"https:\/\/www.novatest.it\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit_Pull_Off-1.png\",\"datePublished\":\"2020-08-07T13:40:58+00:00\",\"dateModified\":\"2025-03-28T09:12:36+00:00\",\"description\":\"Hydraulic system for tear adherence tests on high resistance coating materials.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/#primaryimage\",\"url\":\"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit_Pull_Off-1.png\",\"contentUrl\":\"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit_Pull_Off-1.png\",\"width\":600,\"height\":600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.novatest.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Civil Engineering\",\"item\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"KIT PULL-OFF 500\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.novatest.it\/en\/#website\",\"url\":\"https:\/\/www.novatest.it\/en\/\",\"name\":\"Novatest Srl\",\"description\":\"Produciamo e commercializziamo strumenti tecnologici per la diagnostica non distruttiva.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.novatest.it\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"KIT PULL-OFF 500 - Novatest Srl","description":"Hydraulic system for tear adherence tests on high resistance coating materials.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/","og_locale":"en_US","og_type":"article","og_title":"KIT PULL-OFF 500 - Novatest Srl","og_description":"Hydraulic system for tear adherence tests on high resistance coating materials.","og_url":"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/","og_site_name":"Novatest Srl","article_modified_time":"2025-03-28T09:12:36+00:00","og_image":[{"width":600,"height":600,"url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit_Pull_Off-1.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/","url":"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/","name":"KIT PULL-OFF 500 - Novatest Srl","isPartOf":{"@id":"https:\/\/www.novatest.it\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/#primaryimage"},"image":{"@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/#primaryimage"},"thumbnailUrl":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit_Pull_Off-1.png","datePublished":"2020-08-07T13:40:58+00:00","dateModified":"2025-03-28T09:12:36+00:00","description":"Hydraulic system for tear adherence tests on high resistance coating materials.","breadcrumb":{"@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/#primaryimage","url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit_Pull_Off-1.png","contentUrl":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit_Pull_Off-1.png","width":600,"height":600},{"@type":"BreadcrumbList","@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/kit-pull-off-500\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.novatest.it\/en\/"},{"@type":"ListItem","position":2,"name":"Civil Engineering","item":"https:\/\/www.novatest.it\/en\/civil-engineerings\/"},{"@type":"ListItem","position":3,"name":"KIT PULL-OFF 500"}]},{"@type":"WebSite","@id":"https:\/\/www.novatest.it\/en\/#website","url":"https:\/\/www.novatest.it\/en\/","name":"Novatest Srl","description":"Produciamo e commercializziamo strumenti tecnologici per la diagnostica non distruttiva.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.novatest.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"uagb_featured_image_src":{"full":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit_Pull_Off-1.png",600,600,false],"thumbnail":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit_Pull_Off-1-150x150.png",150,150,true],"medium":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit_Pull_Off-1-300x300.png",300,300,true],"medium_large":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit_Pull_Off-1.png",600,600,false],"large":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit_Pull_Off-1.png",600,600,false],"1536x1536":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit_Pull_Off-1.png",600,600,false],"2048x2048":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit_Pull_Off-1.png",600,600,false],"medium-large":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit_Pull_Off-1.png",520,520,false]},"uagb_author_info":{"display_name":"Uaoh","author_link":"https:\/\/www.novatest.it\/en\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"Hydraulic system for tear adherence tests on high resistance coating materials The Pull-Off is a direct method of proof consists...","img_url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/06\/Kit_Pull_Off-1.png","_links":{"self":[{"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/civil-engineerings\/2698","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/civil-engineerings"}],"about":[{"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/types\/civil-engineerings"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/media\/3447"}],"wp:attachment":[{"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/media?parent=2698"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/categories?post=2698"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/tags?post=2698"},{"taxonomy":"civil_engineerings_cats","embeddable":true,"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/civil_engineerings_cats?post=2698"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}