{"id":2695,"date":"2020-08-07T15:02:43","date_gmt":"2020-08-07T13:02:43","guid":{"rendered":"https:\/\/www.novatest.it\/?post_type=civil-engineerings&#038;p=2695"},"modified":"2025-07-22T12:06:33","modified_gmt":"2025-07-22T10:06:33","slug":"plate-load-test-kit","status":"publish","type":"civil-engineerings","link":"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/","title":{"rendered":"PLATE LOAD TEST KIT"},"content":{"rendered":"\n<p><strong>Complete system for determining the bearing capacity of the soil in compliance with the reference standards<\/strong><\/p>\n\n\n\n<p>Plate Load test is usually used for the verification of the bearing capacity of the land of the substrate, of the foundation layer and the base layer of the flooring, although it is not uncommon to its use to investigate the bearing capacity of the soil surface or to the state compaction of granular materials and road surfaces.<\/p>\n","protected":false},"featured_media":3433,"parent":0,"template":"","categories":[],"tags":[],"civil_engineerings_cats":[207],"class_list":["post-2695","civil-engineerings","type-civil-engineerings","status-publish","has-post-thumbnail","hentry","civil_engineerings_cats-load-testing-en"],"acf":{"specifica_prodotto":"PLATE LOAD TEST KIT","testo_breve_thumb_lista_prodotti":"system for determining the bearing capacity of the soil","contenuto_testuale_del_prodotto":"<p>The test consists in transmitting to the soil to be tested and the subsequent increasing load increments, detecting simultaneously the sagging and therefore allows to directly determine a form of deformation or compressibility of the soil. The load transmission takes place via the application of a force by means of a hydraulic system of thrust, of a circular plate. The subsidence induced by the ground plate are simultaneously detected by centesimal or digital data acquisition systems, integral with a frame of reference outside the area of influence of the applied load. Of fundamental importance, in any case, is the use of the proper contrast medium whose mass is a function of the expected load.<\/p>\n<p>These tests are generally conducted with metal plates of standard diameter fro 300 to 760 millimeters, could be carried out from ground level and inside the wells whose depth is limited only by the size of the jack and related extensions.<\/p>\n<p>Standards: CNR BU 146, SN 670 317 and 670317th, the LCPC method CT2.<\/p>\n","slider":[{"immagine":{"ID":1414,"id":1414,"title":"KIT_PCPiastra_10t-1","filename":"KIT_PCPiastra_10t-1.png","filesize":146912,"url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1.png","link":"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/kit_pcpiastra_10t-1-2\/","alt":"","author":"2","description":"","caption":"","name":"kit_pcpiastra_10t-1-2","status":"inherit","uploaded_to":2695,"date":"2020-07-07 04:12:34","modified":"2020-08-07 12:58:06","menu_order":0,"mime_type":"image\/png","type":"image","subtype":"png","icon":"https:\/\/www.novatest.it\/wp-includes\/images\/media\/default.png","width":581,"height":485,"sizes":{"thumbnail":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1-150x150.png","thumbnail-width":150,"thumbnail-height":150,"medium":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1-300x250.png","medium-width":300,"medium-height":250,"medium_large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1.png","medium_large-width":581,"medium_large-height":485,"large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1.png","large-width":581,"large-height":485,"1536x1536":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1.png","1536x1536-width":581,"1536x1536-height":485,"2048x2048":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1.png","2048x2048-width":581,"2048x2048-height":485,"medium-large":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1.png","medium-large-width":520,"medium-large-height":434}}}],"caratteristiche_tecniche":"<p>&#8211; No.1 Single stage lever pump, working pressure 0-700bar, 1.4 cc \/ pumped, useful tank 0.5 liters (*);<br \/>\n&#8211; No.1 NVT02B high precision digital pressure gauge 0-700bar with indication of min\/max pressure peak, storage of selectable values \u200b\u200band measurement units (psi, MPa, kPa, bar, mbar), accuracy 0,20% F.S. (*);<br \/>\n&#8211; No.1 Adapter for 1\/2\u2033G pressure gauge for connection to a pressure socket;<br \/>\n&#8211; No.1 Hollow piston cylinder, spring return, 10ton pushing force, 50mm stroke (**);<br \/>\n(It is possible to configure the system with jacks of different capacity and stroke)<br \/>\n&#8211; No.1 plate \u00d8 300mm, th. 25mm with adjustable dial gauge support points ;<br \/>\n(Plates of different diameters and thicknesses are also available on request. Standard dimensions: d.760 mm thickness 25 mm, d.600 mm thickness 25 mm, d.450 mm thickness 25 mm)<br \/>\n&#8211; No.1 Articulated head equipped with spherical hinge to center the load;<br \/>\n&#8211; No.1 Extension L=200mm;<br \/>\n&#8211; No.2 Extensions L=100mm;<br \/>\n&#8211; No.3 Extensions L=50mm;<br \/>\n&#8211; No.3 Centesimal analog dial indicator 30mm stroke;<br \/>\n&#8211; No.3 Dial gauge holders (n.3 L = 600mm + n.3 L = 300mm);<br \/>\n&#8211; No.1 Support beam for dial gauge supports L=3000mm composed of two disassemblable blocks L=1500mm each, and equipped with two height-adjustable supports.<\/p>\n<p>(*) Compatible for Flat Jack Kit, STD Pull-Out Kit, Pull-Off 500 Kit, Shove Test;<br \/>\n(**) Compatible for STD Pull-Out Kit, Pull-Off 500 Kit.<\/p>\n","accessori":"<p>The system for plate load tests is supplied with the following standard accessories:<\/p>\n<p>&#8211; No.1 Single-stage manual pump with 0,5Lt tank (*)No.1 NVT02B high precision digital pressure gauge 0-700bar with peak pressure indication, complete with calibration report (Accredia ref.) (*)<br \/>\n&#8211; No.1 Hollow piston cylinder, spring return, 10 ton (100 kN) pushing force, 50mm stroke complete with force\/pressure diagram (**)<br \/>\n&#8211; No.1 plate \u00d8 300mm, 25mm thk;<br \/>\n&#8211; No.1 head with spherical hinge to center the load;<br \/>\n&#8211; No.1 Extension L=200mm;<br \/>\n&#8211; No.2 Extensions L=100mm;<br \/>\n&#8211; No.3 Extensions L=50mm;<br \/>\n&#8211; No.3 centesimal dial gauges, 30mm stroke;<br \/>\n&#8211; No.3 Dial gauge holders;<br \/>\n&#8211; No.1 Support beam for dial gauge supports with adjustable supports.<br \/>\n&#8211; No.1 Rugged hard\u2011shell trolley case for transport and protection of the hydraulic assembly only<\/p>\n<p>Optional accessories:<br \/>\n&#8211; Hollow piston cylinder, spring return, 20 ton (200 kN) pushing force;<br \/>\n&#8211; Plate \u00d8 760mm, 25mm thk;<br \/>\n&#8211; Plate \u00d8 600mm, 25mm thk;<br \/>\n&#8211; Plate \u00d8 450mm, 25mm thk;<\/p>\n<p>(*) compatible for Flat Jack Kit, STD Pull-Out Kit, 500 Pull-Off Kit, Shove Test<br \/>\n(**) compatible for STD Pull-Out Kit and 500 Pull-Off kit<\/p>\n","documento_allegato":[{"file":{"ID":4662,"id":4662,"title":"019 - PLATE LOAD TEST KIT [Eng]","filename":"019-PLATE-LOAD-TEST-KIT-Eng.pdf","filesize":1041922,"url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/08\/019-PLATE-LOAD-TEST-KIT-Eng.pdf","link":"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/019-plate-load-test-kit-eng\/","alt":"","author":"4","description":"","caption":"","name":"019-plate-load-test-kit-eng","status":"inherit","uploaded_to":2695,"date":"2021-02-04 10:15:06","modified":"2021-02-04 10:15:06","menu_order":0,"mime_type":"application\/pdf","type":"application","subtype":"pdf","icon":"https:\/\/www.novatest.it\/wp-includes\/images\/media\/document.png"},"nome_file":"Technical sheet EN"}],"richiedi_noleggio":false,"prodotti_correlati":[{"ID":2725,"post_author":"4","post_date":"2020-08-07 18:11:20","post_date_gmt":"2020-08-07 16:11:20","post_content":"<!-- wp:paragraph -->\n<p><strong>Multiparameter datalogger for in-situ testing and load tests \u2013 up to 24 channels<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>The new NOVAlog data acquisition unit has been redesigned to deliver enhanced performance during in-situ tests, load tests, and monitoring activities.<br>It maintains the core philosophy of the original version\u2014compact design, ease of use, and versatility\u2014while introducing a fully updated hardware platform that is more powerful, lighter, and user-configurable.<\/p>\n<!-- \/wp:paragraph -->","post_title":"NOVALog 3.0","post_excerpt":"","post_status":"publish","comment_status":"closed","ping_status":"closed","post_password":"","post_name":"novalog","to_ping":"","pinged":"","post_modified":"2025-11-28 16:15:45","post_modified_gmt":"2025-11-28 15:15:45","post_content_filtered":"","post_parent":0,"guid":"https:\/\/www.novatest.it\/?post_type=civil-engineerings&#038;p=2725","menu_order":10,"post_type":"civil-engineerings","post_mime_type":"","comment_count":"0","filter":"raw"},{"ID":3211,"post_author":"4","post_date":"2020-09-07 12:51:39","post_date_gmt":"2020-09-07 10:51:39","post_content":"<!-- wp:paragraph -->\n<p><strong>Transducer for crack monitoring, Load Tests and flat jacks tests<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>The isplacement transducers commonly used for the automatic and continuous acquisition of measurements during structural monitoring or load tests.<br>Completely made of stainless steel, they can be equipped with eyelets for wall fixing or with spring testator for load tests with suitable support bracket and telescopic stand. Available with different measurement ranges.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>The electronic crack meter consists of a potentiometric-type displacement sensor that detects changes in position between two points straddling a lesion or a joint.<br>It is made entirely of aluminum, nylon and stainless steel and is equipped with self-aligning joints and a whole range of optional accessories for correct installation even in the most difficult cracking situations (cracks at corners, edges, etc.).<br>The electric crack meter is a valid tool for manual or automatic control of the measurements of small displacements.<br>The data can be read through the use of a portable control unit or through an automatic data acquisition system designed to carry out continuous monitoring.<\/p>\n<!-- \/wp:paragraph -->","post_title":"NOVA TR50\/FS50","post_excerpt":"","post_status":"publish","comment_status":"closed","ping_status":"closed","post_password":"","post_name":"nova-tr50-fs50","to_ping":"","pinged":"","post_modified":"2025-09-24 10:23:40","post_modified_gmt":"2025-09-24 08:23:40","post_content_filtered":"","post_parent":0,"guid":"https:\/\/www.novatest.it\/?post_type=civil-engineerings&#038;p=3211","menu_order":18,"post_type":"monitoring-systems","post_mime_type":"","comment_count":"0","filter":"raw"},{"ID":9765,"post_author":"4","post_date":"2025-05-16 11:08:30","post_date_gmt":"2025-05-16 09:08:30","post_content":"<!-- wp:paragraph -->\n<p>The Novatest POT system is a complete and modular solution designed to perform mechanical tests on steel profiles driven into the ground, essential for assessing load-bearing capacity and soil-structure interaction in photovoltaic, agrivoltaic, and road infrastructure projects. The tests include:<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Vertical compression test<\/strong>: assesses the axial load-bearing resistance of the pile.<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Lateral pull-out test<\/strong>: simulates horizontal loads, such as wind pressure or lateral vehicle impacts.<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Vertical pull-out test<\/strong>: evaluates the resistance of the pile to being pulled out from the ground.<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>These tests are essential to ensure the stability and safety of both solar panel support structures and guardrail posts, by verifying proper anchorage to the ground and resistance to natural and dynamic loads such as wind, snow, and vehicular impacts.<\/strong><\/p>\n<!-- \/wp:paragraph -->","post_title":"KIT POT","post_excerpt":"","post_status":"publish","comment_status":"closed","ping_status":"closed","post_password":"","post_name":"kit-pot","to_ping":"","pinged":"","post_modified":"2025-09-08 18:03:21","post_modified_gmt":"2025-09-08 16:03:21","post_content_filtered":"","post_parent":0,"guid":"https:\/\/www.novatest.it\/civil-engineerings\/kit-pot\/","menu_order":35,"post_type":"civil-engineerings","post_mime_type":"","comment_count":"0","filter":"raw"}],"sokkia":false},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>PLATE LOAD TEST KIT - Novatest Srl<\/title>\n<meta name=\"description\" content=\"Complete system for determining the bearing capacity of the soil in compliance with the reference standards.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PLATE LOAD TEST KIT - Novatest Srl\" \/>\n<meta property=\"og:description\" content=\"Complete system for determining the bearing capacity of the soil in compliance with the reference standards.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/\" \/>\n<meta property=\"og:site_name\" content=\"Novatest Srl\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-22T10:06:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/\",\"url\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/\",\"name\":\"PLATE LOAD TEST KIT - Novatest Srl\",\"isPartOf\":{\"@id\":\"https:\/\/www.novatest.it\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1-1.png\",\"datePublished\":\"2020-08-07T13:02:43+00:00\",\"dateModified\":\"2025-07-22T10:06:33+00:00\",\"description\":\"Complete system for determining the bearing capacity of the soil in compliance with the reference standards.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/#primaryimage\",\"url\":\"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1-1.png\",\"contentUrl\":\"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1-1.png\",\"width\":600,\"height\":600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.novatest.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Civil Engineering\",\"item\":\"https:\/\/www.novatest.it\/en\/civil-engineerings\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"PLATE LOAD TEST KIT\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.novatest.it\/en\/#website\",\"url\":\"https:\/\/www.novatest.it\/en\/\",\"name\":\"Novatest Srl\",\"description\":\"Produciamo e commercializziamo strumenti tecnologici per la diagnostica non distruttiva.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.novatest.it\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"PLATE LOAD TEST KIT - Novatest Srl","description":"Complete system for determining the bearing capacity of the soil in compliance with the reference standards.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/","og_locale":"en_US","og_type":"article","og_title":"PLATE LOAD TEST KIT - Novatest Srl","og_description":"Complete system for determining the bearing capacity of the soil in compliance with the reference standards.","og_url":"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/","og_site_name":"Novatest Srl","article_modified_time":"2025-07-22T10:06:33+00:00","og_image":[{"width":600,"height":600,"url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1-1.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/","url":"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/","name":"PLATE LOAD TEST KIT - Novatest Srl","isPartOf":{"@id":"https:\/\/www.novatest.it\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/#primaryimage"},"image":{"@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/#primaryimage"},"thumbnailUrl":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1-1.png","datePublished":"2020-08-07T13:02:43+00:00","dateModified":"2025-07-22T10:06:33+00:00","description":"Complete system for determining the bearing capacity of the soil in compliance with the reference standards.","breadcrumb":{"@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/#primaryimage","url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1-1.png","contentUrl":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1-1.png","width":600,"height":600},{"@type":"BreadcrumbList","@id":"https:\/\/www.novatest.it\/en\/civil-engineerings\/plate-load-test-kit\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.novatest.it\/en\/"},{"@type":"ListItem","position":2,"name":"Civil Engineering","item":"https:\/\/www.novatest.it\/en\/civil-engineerings\/"},{"@type":"ListItem","position":3,"name":"PLATE LOAD TEST KIT"}]},{"@type":"WebSite","@id":"https:\/\/www.novatest.it\/en\/#website","url":"https:\/\/www.novatest.it\/en\/","name":"Novatest Srl","description":"Produciamo e commercializziamo strumenti tecnologici per la diagnostica non distruttiva.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.novatest.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"uagb_featured_image_src":{"full":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1-1.png",600,600,false],"thumbnail":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1-1-150x150.png",150,150,true],"medium":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1-1-300x300.png",300,300,true],"medium_large":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1-1.png",600,600,false],"large":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1-1.png",600,600,false],"1536x1536":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1-1.png",600,600,false],"2048x2048":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1-1.png",600,600,false],"medium-large":["https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1-1.png",520,520,false]},"uagb_author_info":{"display_name":"Uaoh","author_link":"https:\/\/www.novatest.it\/en\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"Complete system for determining the bearing capacity of the soil in compliance with the reference standards Plate Load test is...","img_url":"https:\/\/www.novatest.it\/wp-content\/uploads\/2020\/07\/KIT_PCPiastra_10t-1-1.png","_links":{"self":[{"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/civil-engineerings\/2695","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/civil-engineerings"}],"about":[{"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/types\/civil-engineerings"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/media\/3433"}],"wp:attachment":[{"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/media?parent=2695"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/categories?post=2695"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/tags?post=2695"},{"taxonomy":"civil_engineerings_cats","embeddable":true,"href":"https:\/\/www.novatest.it\/en\/wp-json\/wp\/v2\/civil_engineerings_cats?post=2695"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}